HP ProLiant DL360 G5 Server User Manual
Page 59
Hardware options installation 59
16.
Connect and route the battery pack power cable to the HP Smart Array P400i Controller cache
module.
17.
Install fan modules 1 and 2 ("
Remove and install a fan module
18.
Install the air baffle.
19.
Install the access panel (on page
20.
Slide the server into the rack.
21.
Power up the server (on page
Upgrading the HP Smart Array P400i Controller to support six hard drives
In certain configurations, the server may ship configured with the HP Smart Array P400i Controller and
only one data cable installed. To enable support for six hard drives, install an optional Mini-SAS 4i
0.35 m (14 in) cable from the HP Smart Array P400i Controller to the hard drive backplane.
1.
Power down the server (on page
2.
Extend the server from the rack (on page
3.
Remove the access panel (on page
4.
Remove the power supply air baffle
" on page
5.
Remove fan modules 1 and 2 ("
Remove and install a fan module
" on page
6.
Connect and route the second cable.
CAUTION: When routing cables, use the cable trough between fan modules 1 and 2. Be sure the cables
do not interfere with fan module installation. Be sure to route the cables around the access panel mounting
pin bracket so as not to interfere with access panel installation.