beautypg.com

Installing fbdimms, Hot-plug sas and sata hard drive options – HP ProLiant DL360 G5 Server User Manual

Page 40

background image

Hardware options installation 40

Banks A and B must be fully populated.

Bank A and bank B must contain FBDIMMs with identical part numbers. If installed, bank C and
bank D must also contain FBDIMMs with identical part numbers.

When using mirrored memory mode, FBDIMMs must be populated as specified in the following table:

Configuration Bank

A

1A and 3A

Bank B

5B and 7B

Bank C

2C and 4C

Bank D

6D and 8D

1 X X — —

2 X X X X

After installing FBDIMMs, use RBSU to configure the system for mirrored memory support ("

Configuring

mirrored memory

" on page

69

).

Installing FBDIMMs

1.

Power down the server (on page

18

).

2.

Extend the server from the rack (on page

19

).

3.

Remove the access panel (on page

20

).

4.

Open the FBDIMM slot latches.

5.

Install the FBDIMM.

6.

Install the access panel (on page

20

).

7.

Slide the server into the rack.

8.

If you are installing FBDIMMs in an online spare or mirrored configuration, use RBSU ("

HP ROM-

Based Setup Utility

" on page

68

) to configure this feature.

Hot-plug SAS and SATA hard drive options

When adding hard drives to the server, observe the following general guidelines:

The system automatically sets all device numbers.

If only one hard drive is used, install it in the bay with the lowest device number ("

SAS and SATA

device numbers

" on page

15

).