beautypg.com

Drive array status, Drive array inventory, Logical drive – HP Insight Control User Manual

Page 58: Logical drive status, Logical drive inventory, Smart array scsi drive, Drive array status drive array inventory, Logical drive status logical drive inventory

background image

Drive Array Status

Reads/Sec—The number of reads from each drive in the drive array each second

Writes/Sec—The number of writes to each drive in the drive array each second

Read MBytes/Sec—The average number of megabytes read from each drive in the drive array each
second

Write MBytes/Sec—The average number of megabytes written to each drive in the drive array each
second

Millisec/Read—The average time for each read to complete

Millisec/Write—The average time for each write to complete

Queue Length—The average number of concurrent requests between the server and each drive in the
drive array, including transfers currently being serviced and transfers waiting for service, regardless of
where the request is waiting (drive or controller)

Drive Array Inventory

Array Configuration—Displays on which Smart controller the drive array is defined and the number of
array logical drives implemented on the array

Hard Drives—Lists the SCSI drives constituting the disk array

Spare Drives—Lists the SCSI drives designated as spares

Logical drive

The following information is provided for a logical drive.

Logical Drive Status

Reads/Sec—The number of reads from this logical drive each second

Writes/Sec—The number of writes to this logical drive each second

Read MBytes/Sec—The number of megabytes read from the logical drive each second

Write MBytes/Sec—The number of megabytes written to the logical drive each second

Millisec/Read—The average time for each read to complete

Millisec/Write—The average time for each write to complete

Queue Length—The average number of concurrent requests between the server and this logical drive,
including transfers currently being serviced and transfers waiting for service, regardless of where the
request is waiting (disk or controller)

Logical Drive Inventory

Logical Drive Configuration

The controller on which the logical drive is defined

The array label (such as A, B, or C) as shown by the Array Configuration Utility (ACU)

The logical drive number as assigned by the ACU and the physical disk mapping

Logical drive size in megabytes

The RAID level for this logical drive

The logical drive striping factor

Whether caching is enabled for this logical drive

Smart Array SCSI drive

The following information is provided for a Smart Array SCSI drive.

58

Measurement parameter matrix