Output descriptions, Query example – HP XP P9500 Storage User Manual
Page 81

QUERY example
Output descriptions
The following table shows the field descriptions of the output resulting when CQUERY TSO and
QUERY ICKDSF
commands are run.
Table 21 Field descriptions for CQUERY TSO and the QUERY ICKDSF command output
Description
Field
Device number of the volume on which the CQUERY command is issued.
DEVICE
PRIMARY indicates that the volume is a P-VOL. SECONDARY indicates that the volume
is a T-VOL.
LEVEL
Pair status
STATE
Invalid for BC; Active is shown.
PATH STATUS
Invalid for BC; NO is shown.
CRIT
Invalid for BC; NO is shown.
CGRPLB
SSID of the P-VOL CU
PRIMARY-SSID
P-VOL LDEV number
PRIMARY-CCA
P-VOL CU number
PRIMARY-LSS
P-VOL serial number
PRIMARY-SERIAL
SSID of the S-VOL CU
SECONDARY-SSID
S-VOL LDEV number
SECONDARY-CCA
S-VOL CU number
SECONDARY-LSS
S-VOL serial number. Running the CQUERY TSO command for the S-VOL also show
following information:
SECONDARY-SERIAL
00ab000nnnnn
where a indicates that the pair is defined as a consistency group and b indicates the
pair was split using At-Time Split. 0 indicates otherwise. nnnnn is the S-VOL serial number.
Showing pair information with CQUERY TSO, QUERY ICKDSF
81
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (85 pages)
- Software de HP StoreVirtual VSA (127 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)