HP XP P9500 Storage User Manual
Page 33

Table 5 Volume access attribute and BC Z pair operations
BC Z operations
Volume access attributes specified for the BC Z pair
Delete
Resync (reverse)
Create, Split, Suspend,
Resync (forward)
S-VOL
P-VOL
YES
YES
YES
Read/Write or Read Only
Read/Write
YES
NO
NO
Protect
YES
YES
YES
Read/Write or Read Only
Read Only
YES
NO
NO
Protect
YES
NO
NO
Read/Write, Read Only, or Protect
Protect
Table 6 Access attributes and BC Z reserve attribute change operations
BC Z reserve attribute change operation
Volume access attributes specified
by BC Z
Removing reserve attribute
Setting reserve attribute
YES
YES
Read/Write or Read Only
YES
NO
Protect
Business Copy Z pair statuses and access attribute setting
You can use Volume Retention to set access attributes to BC Z P-VOLs and S-VOLs.
For BC Z reserve volumes, you can set all of the following Volume Retention access attributes:
•
Read/Write
•
Read Only
•
Protect
CAUTION:
For 3390-A volumes, an attempt to set the Read Only attribute or Protect attribute on
a P-VOL or S-VOL may result in termination of copy processing or pair suspension.
Volume Retention
33
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)