Table 7 RAID Manager Error Codes (continued)

Description

SSB2 code

The pair operation was rejected for one of the following reasons:

205B

An MU number already in use was specified.

MU number 0 was assigned to an L2 pair.

The volume you specified as a P-VOL was a volume of a Cnt Ac-J pair. The pair operation was rejected
because the status of the Cnt Ac-J pair was invalid.

2060

The volume you specified as an S-VOL was a volume of a Cnt Ac-J pair. The pair operation was
rejected because the status of the Cnt Ac-J pair was invalid.

2061

The volumes you specified for the pair were shared by Cnt Ac-S and Cnt Ac-J. The Quick Restore or
reverse copy operation was rejected because the Cnt Ac-S or Cnt Ac-J pair was not split (Split/SUSPOP
status).

2067

The pair operation was rejected because the P-VOL or S-VOL you specified was being shredded.

2068

The pair operation was rejected for one of the following reasons:

2072

The P-VOL was also a FS or SS pool volume.

The P-VOL was also a FS or SS secondary volume, or V-VOL.

The P-VOL was also a FS or SS P-VOL, and one of the following conditions was also true.

- While the FS or SS pair was restored, the create, split, or resync pair operation was performed
on the BC Z pair.

- The BC Z Quick Restore operation was performed.

- A consistency group was defined for BC Z.

- After the MU number used by a FS or SS pair was specified, the create, split, or resync pair
operation was performed on the BC Z pair.

The pair operation was rejected for one of the following reasons:

2073

The S-VOL was also an FS or SS pool volume.

The S-VOL was also an FS or SS secondary volume, or V-VOL.

The S-VOL was an FS or SS S-VOL pair, and one of the following conditions was also true.

- The FS or SS pair was being restored.

- The BC Z Quick Restore operation was performed.

- A create pair operation was performed on the BC Z pair.

Because the P-VOL you specified was also a Cnt Ac-J P-VOL for delta resync, one of the following
errors occurred:

2078

The reverse copy operation was rejected because the Cnt Ac-J pair was not split (Split/SUSPOP
status).

The Quick Restore operation was rejected.

The pair operation was rejected because the P-VOL you specified was also a Cnt Ac-J P-VOL for delta
resync.

2079

The pair operation was rejected because the initialization process was being performed.

2086

The Quick Restore operation was rejected because the volume you specified as a P-VOL was undergoing
quick format

2089

The Quick Restore operation was rejected because the volume you specified as an S-VOL was
undergoing quick format.

208A

The pair operation was rejected because the volume you specified as the S-VOL was a FICON(R)
Data Migration volume.

208C

The volume you specified as a P-VOL was a Cnt Ac-S S-VOL. The split operation was rejected because
the status of the Cnt Ac-S pair was not Suspend.

2093

Troubleshooting with RAID Manager

59