beautypg.com

9 array mapping, Xp48/128 (1 acp pair), Xp 48/128 (2 acp pairs) – HP XP Performance Advisor Software User Manual

Page 95

background image

9 Array mapping

To correctly map the ACP and CHIP pairs, see the following tables for the respective array:

Table 2

lists 1 ACP pair for disk array XP48/128.

NOTE:

The cards are lettered A-M, omitting I.

Table 2 XP48/128 (1 ACP Pair)

B, L

ACP Pair 1

ACP B = 0; L = 4

C, G

CHIP Pair 1

Chip C = 0; G = 4

D, J

CHIP Pair 2

Chip D = 1; J = 5

F, K

CHIP Pair 3

Chip F = 2; K = 6

Table 3

lists the 2 ACP pairs for disk array XP48/128.

NOTE:

The cards are lettered A-M, omitting I.

Table 3 XP 48/128 (2 ACP Pairs)

B, L

ACP Pair 1

ACP B = 0; L = 4

F, K

ACP Pair 2

ACP F = 1; K = 5

C, G

CHIP Pair 1

Chip C = 0; G = 4

D, J

CHIP Pair 2

Chip D = 1; J = 5

Table 4

lists the ACP and CHIP pairs for XP256/512/1024.

NOTE:

The cards are lettered A-Z, omitting I and O; with 12 cards on the back (A-M) and 12 on the front (N-Z).

HP StorageWorks Performance Advisor XP Software command-line user interface user guide

95