HP StorageWorks XP Remote Web Console Software User Manual
Page 114
Table 33 Cause of Error and the Result of RAID Manager Command (SSB) (continued)
Cause of Error
RAID Manager Command
SSB2
SSB1
The XP Snapshot pair cannot
be created because the
specified consistency group
number is out of the range
of the number that can be
specified.
The snapshot data cannot be
stored because the XP
Continuous Access
asynchronous pair status is
other than PSUS or PSUE
when XP Snapshot (P-VOL)
and XP Continuous Access
asynchronous (S-VOL) share
the volume.
pairsplit
978c
The XP Snapshot pair for
which the consistency group
is specified cannot be
created because the P-VOL
or S-VOL of the XP Business
Copy pair is specified as the
P-VOL of the XP Snapshot
pair.
paircreate
978e
The XP Thin Provisioning
virtual volume, which is
undergoing capacity
expansion, is specified as
the XP Snapshot P-VOL.
Therefore, the XP Snapshot
pair cannot be created.
paircreate
9790
The XP Snapshot pair cannot
be created because the XP
Thin Provisioning V-VOL that
is discarding zero data is
specified as a P-VOL of the
XP Snapshot pair.
paircreate
9793
The command ended
abnormally because the
specified S-VOL used two
mirrors in a 3DC multi-target
or 3DC cascade
configuration, which is a
delta resync configuration
consisting of three XP
Continuous Access Journal
sites.
paircreate
pairsplit
pairresync
pairresync -restore
97a2
The command ended
abnormally because the
specified S-VOL used two
mirrors in a 3DC multi-target
or 3DC cascade
configuration, which is a
delta resync configuration
consisting of three XP
Continuous Access Journal
sites.
paircreate
pairsplit
pairresync
pairresync -restore
97a3
B912
114