Table 33 Cause of Error and the Result of RAID Manager Command (SSB) (continued)
Cause of Error
RAID Manager Command
SSB2
SSB1
The command ended
abnormally because the pair
is in the status that the
corresponding command is
not accepted at present.
This error also may be
reported when the command
is executed with specifying
an unsupported parameter.
Since the capacity of shared
memory is insufficient, the
pair cannot be created.
paircreate
971a
Since the attribute of the
specified pool is other than
XP Snapshot, an XP
Snapshot pair cannot be
created.
paircreate
971b
Since the volume you
specified as the P-VOL has
an S-VOL Disable attribute,
an XP Snapshot pair cannot
be restored.
pairresync -
restore
971f
Any errors have occurred
because of the XP Snapshot
operation.
All commands
9720
Since either XP Snapshot or
XP Business Copy Software
is not installed, the
command ends abnormally.
paircreate
pairsplit
pairresync
pairresync -
restore
9721
Because of no additional
shared memory (FCV2, TPF,
Extention1), the command
ends abnormally.
All commands
9723
Because of no additional
shared memory (more than
XP1), the command ends
abnormally.
All commands
9724
Since the LDEV number of
the volume you specified as
the P-VOL is beyond the
specified range, the
command ends abnormally.
All commands
9725
Since you specified the
unmounted volume as the XP
Snapshot P-VOL, the
command ends abnormally.
All commands
9726
Since you specified the
blocked volume as the XP
Snapshot P-VOL, the
command ends abnormally.
9727
Troubleshooting When Using XP RAID Manager 105