beautypg.com

HP ProLiant DL365 G5 Server User Manual

Page 60

background image

Hardware options installation 60

7.

Disconnect the hard drive backplane power cable from the system board.

8.

Turn the quarter-turn fasteners counter-clockwise and lift the integrated array controller away from the
system board.

9.

Connect the hard drive backplane power cable to the system board.

10.

Install and route the cables from the PCI SAS or SATA array controller to the SAS hard drive
backplane.

CAUTION:

When routing cables, use the cable trough between fan modules 1 and 2. Be sure

the cables do not interfere with fan module installation. Be sure to route the cables around the
access panel mounting pin bracket so as not to interfere with access panel installation.

CAUTION:

When routing cables, always be sure that the cables are not in a position where

they can be pinched or crimped.

11.

Install fan modules 1 and 2 ("

Remove and install a fan module

" on page

23

).

12.

Install the air baffle ("

Remove and install the air baffle

" on page

20

).