Display LED and color
Internal health
LED color
Status
PPM failure (amber)
Red
Integrated PPM has failed.
DIMM failure, slot X
(amber)
Red
One or more of the following conditions may exist:
•
DIMM in slot X has failed.
•
DIMM in slot X is an unsupported type, and no valid
memory exists in another bank.
Amber
One or more of the following conditions may exist:
•
DIMM in slot X has reached single-bit correctable
error threshold.
•
DIMM in slot X is in a pre-failure condition.
•
DIMM in slot X is an unsupported type, but valid
memory exists in another bank.
DIMM failure, all slots
(amber)
Red
No valid or usable memory is installed in the system.
Overtemperature (amber) Amber
The health driver has detected a cautionary temperature
level.
Red
The server has detected a critical temperature level.
Riser interlock (amber)
Red
The PCI riser board assembly is not seated properly.
Fan module (amber)
Amber
A redundant fan has failed.
Fan module (amber)
Red
The minimum fan requirements are not being met in one
or more of the fan modules. One or more fans have failed
or are missing.