beautypg.com

Installing the mini-sas p830 cable in a 2u node – HP ProLiant SL210t Gen8 Server User Manual

Page 53

background image

Hardware options installation 53

9.

Route the cable through the air baffle, and then connect the cable to the connector on the adapter
board.

10.

Install the 2U adapter board bracket (on page

23

).

11.

Install the PCI riser cage (on page

21

).

12.

Install the node into the chassis ("

Installing a node into the chassis

" on page

30

).

13.

Connect all peripheral cables to the node.

14.

Power up the node ("

Power up the nodes

" on page

17

).

Installing the Mini-SAS P830 cable in a 2U node

1.

Power down the node (on page

17

).

2.

Disconnect all peripheral cables.

3.

Remove the node from the chassis (on page

17

).

4.

Remove the PCI riser cage (on page

20

).

5.

Remove the 2U adapter board bracket (on page

22

).

6.

Disconnect and remove the Mini-SAS cable ("

Remove the Mini-SAS cable

" on page

23

).

7.

If not installed, install a P830 Smart Array controller into the PCI riser cage ("

Installing an expansion

board

" on page

42

).

8.

Connect the Mini-SAS Y-cables:

a.

Connect the Mini-SAS Y-cable x8 connectors to the P830 Smart Array controller.

b.

Route the right-angle cable through the air baffle, and then connect the two ends of the cable to the
corresponding connectors on the bottom adapter board.

c.

Install the 2U adapter board bracket (on page

23

).