Specifications, Environmental specifications, Server specifications – HP ProLiant DL160 Gen8 Server User Manual
Page 91: Power supply specifications

Specifications 91
Specifications
Environmental specifications
Specification
Value
Temperature range*
Operating
10°C to 35°C (50°F to 95°F)
Nonoperating
-30°C to 60°C (-22°F to 140°F)
Relative humidity
(noncondensing)
Operating, maximum wet bulb
temperature of 28°C (82.4°F)
10% to 90%
Nonoperating, maximum wet
bulb temperature of 38.7°C
(101.7°F)
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
Server specifications
Specification
Value
Height
4.32 cm (1.70 in)
Depth (chassis with SFF drive
cage)
69.9 cm (27.5 in)
Depth (chassis with LFF drive cage) 75.0 cm (29.5 in)
Width
43.46 cm (17.11 in)
Weight (maximum SFF: two
processors, one power supply,
eight drives)
16.9 kg (37.25 lb)
Weight (maximum LFF: two
processors, one power supply,
four drives)
17.6 kg (38.80 lb)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
•
HP 460 W CS Power Supply (94%) specifications
•
HP 750 W CS Power Supply (94%) specifications
•
HP 500 W Multi-output Power Supply specifications
•
HP 750 W DC CS Power Supply (94%) specifications