Population order, Installing a dimm – HP ProLiant DL160 Gen8 Server User Manual
Page 51
![background image](/manuals/397950/51/background.png)
Hardware options installation 51
Population order
For memory configurations with a single processor or multiple processors, populate the DIMM slots in the
following order:
•
LRDIMM: Sequentially in alphabetical order (A through L)
•
RDIMM: Sequentially in alphabetical order (A through L)
•
UDIMM: A through H, sequentially in alphabetical order. Do not populate DIMM slots I through L.
After installing the DIMMs, use RBSU to configure Advanced ECC, online spare, or lockstep memory support.
Installing a DIMM
1.
Power down the server (on page
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
o
Remove the server from the rack (on page
4.
Remove the access panel (on page
5.
Remove the processor air baffle (on page
6.
Open the DIMM slot latches.
7.
Install the DIMM.
8.
Install the processor air baffle (on page
9.
Install the access panel (on page
10.
Slide the server into the rack.
11.
Connect each power cord to the server.
12.
Connect each power cord to the power source.
13.