Installing the fbwc module and capacitor pack – HP ProLiant DL160 Gen8 Server User Manual

Page 39

background image

Hardware options installation 39

1.

Power down the server (on page

16

).

2.

Remove all power:

a.

Disconnect each power cord from the power source.

b.

Disconnect each power cord from the server.

3.

Do one of the following:

o

Extend the server from the rack (on page

17

).

o

Remove the server from the rack (on page

16

).

4.

Remove the access panel (on page

19

).

5.

Install the storage controller.

6.

Connect all cabling to the Smart Array controller. For more information see the document included with
the controller option.

7.

Install the access panel (on page

19

).

8.

Install the server into the rack ("

Installing the server into the rack

" on page

28

).

9.

Install the drives ("

Drive options

" on page

31

).

CAUTION:

To prevent improper cooling and thermal damage, do not operate the server unless

all bays are populated with either a component or a blank.

10.

Power up the server (on page

16

).

To configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP

website (

http://www.hp.com/support/CASAC_RG_en

).

Installing the FBWC module and capacitor pack

1.

Power down the server (on page

16

).

2.

Remove all power:

a.

Disconnect each power cord from the power source.

b.

Disconnect each power cord from the server.

3.

Do one of the following:

o

Extend the server from the rack (on page

17

).

o

Remove the server from the rack (on page

16

).

4.

Remove the access panel (on page

19

).

5.

Remove the processor air baffle (on page

20

).

6.

Remove the PCI riser cage (on page

21

).

CAUTION:

When connecting or disconnecting the capacitor pack cable, the connectors on the

cache module and cable are susceptible to damage. Avoid excessive force and use caution to

avoid damage to these connectors.