Description
Item
•
Emulation Type: P-VOL's emulation type
•
Capacity: P-VOL's volume capacity
•
CLPR: P-VOL's CLPR number
The copy type.
Copy Type
Values:
•
BC-L1: BC/SS L1 pair
•
BC-L2: BC/SS L2 pair
•
FS: FS pair
•
SS: SS pair
•
BC Z: BC Z pair
The snapshot group name.
Snapshot Group
A hyphen (-) is shown for non-FS pairs.
If you do not configure a snapshot group for a FS pair, this item is blank.
The pair status.
Status
For more information, see
“Pair status definitions” (page 51)
The S-VOL information includes:
Secondary Volume
•
LDEV ID: S-VOL's LDEV identifier
•
LDEV Name: S-VOL's LDEV name
•
Emulation type: S-VOL's emulation type
•
Capacity: S-VOL's volume capacity
•
CLPR: S-VOL's CLPR number
The date and time that a snapshot was acquired.
Snapshot Date
A hyphen (-) is shown for non-FS pairs or non-SS pairs.
The pool name and identification number.
Pool Name (ID)
A hyphen (-) is shown for non-FS pairs or non-SS pairs.
The copy speed.
Copy Pace
A hyphen (-) is shown for FS pairs and SS pairs.
The mirror unit number.
Mirror Unit
Click to open the Pair Properties window.
Detail button
Create Pair wizard
Use this wizard to create pairs. See
“Creating Fast Snap pairs” (page 41)
for information.
Create Pair wizard
93
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)