beautypg.com

Installing the cache module – HP ProLiant ML370 G6 Server User Manual

Page 85

background image

Hardware options installation 85

CAUTION:

Do not use this controller with cache modules designed for other controller models,

because the controller can malfunction and you can lose data. Also, do not transfer this cache

module to a different controller module, because you can lose data.

CAUTION:

To prevent a server malfunction or damage to the equipment, do not add or remove

the battery pack while an array capacity expansion, RAID level migration, or stripe size migration
is in progress.

CAUTION:

After the server is powered down, wait 15 seconds and then check the amber LED

before unplugging the cable from the cache module. If the amber LED blinks after 15 seconds, do

not remove the cable from the cache module. The cache module is backing up data, and data is

lost if the cable is detached.

IMPORTANT:

The battery pack might have a low charge when installed. In this case, a POST

error message is displayed when the server is powered up, indicating that the battery pack is

temporarily disabled. No action is necessary on your part. The internal circuitry automatically
recharges the batteries and enables the battery pack. This process might take up to four hours.

During this time, the cache module functions properly, but without the performance advantage of

the battery pack.

NOTE:

The data protection and the time limit also apply if a power outage occurs. When power

is restored to the system, an initialization process writes the preserved data to the hard drives.

Installing the cache module

CAUTION:

Do not use this controller with cache modules designed for other controller models,

because the controller can malfunction and you can lose data. Also, do not transfer this cache

module to a different controller module, because you can lose data.

To install the component:

1.

Back up all data.

2.

Close all applications.

3.

Power down the server (on page

22

).

CAUTION:

In systems that use external data storage, be sure that the server is the first unit to be

powered down and the last to be powered back up. Taking this precaution ensures that the system

does not erroneously mark the drives as failed when the server is powered up.

4.

Do one of the following:

o

Unlock and remove the bezel ("

Open or remove the tower bezel

" on page

22

).

o

Extend the server from the rack (on page

24

).

5.

Remove the access panel (on page

25

).

This manual is related to the following products: