Two-bay lff drive cage option – HP ProLiant ML370 G6 Server User Manual
Page 69

Hardware options installation 69
12.
Route and connect the SAS cables.
13.
Install the fan cage.
14.
Install the air baffle.
15.
Install fan 5.
16.
If removed, install the BBWC battery pack or the FBWC capacitor pack ("
pack or the FBWC capacitor pack
" on page
17.
Install the access panel.
18.
Do one of the following:
o
Close or install the tower bezel, as needed.
o
Slide the server back into the rack.
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
19.
Install the hard drives and hard drive blanks.
20.
Powering up and configuring the server
" on page
Two-bay LFF drive cage option
To configure this option for drive cage bay 3, locate the three jumper pins on the backplane. Move the
jumper from pins 1 and 2 to pins 2 and 3.
For more information, see "Drive cage jumper configuration settings (on page
)."
To install the component:
1.
Power down the server (on page
2.
Do one of the following:
o
Open or remove the tower bezel, as needed ("
Open or remove the tower bezel
" on page
o
Extend the server from the rack (on page