Windows Server environments 36
The following table lists common Event Log error messages, along with suggested solutions.
Message
Suggested solution
Error: ioDrive(x)
firmware is too
old. The firmware
must be updated.
To update the firmware, see "Upgrading the device firmware using Windows (on page
)."
Error: The
ioDrive(x)
initialization
failed with error
code 0xerrorcode
(where errorcode is a
number which might
vary)
1
Reinstall the Windows driver.
2
Remove and reseat the IO Accelerator device.
3
Remove the IO Accelerator and insert it in a different slot.
Error: The
ioDrive(x) was not
attached. Use the
fio-attach
utility to rebuild
the drive.
This error might appear after an unmanaged shutdown. You can use either the
fio-attach command line utility or HP IO Manager to re-attach the IO Accelerator.
This attach process might take up to ten minutes as the utility performs a consistency
check on the drives.
Warning: The
ioDrive(x) was not
attached because
auto-attach is
disabled.
The IO Accelerator must attach to the Windows operating system to be available to
users and applications. This attach normally occurs at boot time. As part of this attach
process, the IO Accelerator driver verifies the presence of an AutoAttach parameter
in the Windows® registry. If you create this Registry parameter to disable auto-attach,
the attach operation does not complete.
To attach an unattached IO Accelerator:
1
Run the HP IO Accelerator Management Tool.
2
Select your unattached IO Accelerator from the Device Tree.
3
Click Attach.
4
Confirm the Attach operation.
Your IO Accelerator now attaches to the Windows® operating system. To re-enable
auto attach at boot time, see "Enabling auto attach ("
" on page
)."