beautypg.com

Universal replicator for z/os, Software error codes – HP StorageWorks XP Remote Web Console Software User Manual

Page 301

background image

Troubleshooting

7

Hitachi Universal Replicator for IBM /OS User’s Guide

Primary
storage
system
hardware or
secondary
storage
system
hardware

Hardware redundancy has been lost due to
some blockade condition. As a result, one of the
following could not complete: primary-secondary
storage system communication, journal creation,
copy operation, restore operation, staging
process, or de-staging process.

Journals cannot be retained because some portion of

the cache memory or the shared memory has been

blocked due to hardware failure.
The primary storage system failed to create and

transfer journals due to unrecoverable hardware

failure.
The secondary storage system failed to receive and

restore journals due to unrecoverable hardware

failure.
The drive parity group was in correction-access

status while the URz pair was in Pending Duplex

status.

DC0
x
DC1
x
DC2
x

According to SIM, remove the
hardware blockade or failure.

Restore the failed volume pairs (Resume

Pair).
If a failure occurs when Business

Continuity Manager is being used,

secondary volumes in Suspend

(equivalent to SWAPPING in Business

Continuity Manager) may remain in the

master journal group. If these volumes

remain, execute the YKRESYNC

REVERSE option on the secondary

volumes whose pair status is Suspend,

which is equivalent to SWAPPING in

Business Continuity Manager

terminology (YKRESYNC is the

Business Continuity Manager command

for resynchronizing pair). This operation

changes all volumes in the master

journal group to primary volumes. After

this operation, restore the volume pairs

(Resume Pair).

Communicatio
n between the
primary and
secondary
storage
systems

Communication between the storage systems
failed because the secondary storage system or
network relay devices were not running.

Journal volumes remained full even after the timeout

period elapsed.

DC0
x
DC1
x

Remove the failure from the primary
and secondary storage systems or
the network relay devices.

If necessary, increase resources as

needed (e.g., the amount of cache, the

number of paths between primary and

secondary storage systems, the parity

groups for journal volumes, etc.).
Restore the failed pairs (Resume Pair).

RIO overload
or RIO failure

An unrecoverable RIO (remote I/O) timeout
occurred because the storage system or
networks relay devices were overloaded. Or, RIO
could not be finished due to a failure in the
storage system.

DC2
x

Release failed pairs (Delete Pair).

If necessary, increase resources as

needed (e.g., the amount of cache, the

number of paths between primary and

secondary storage systems, the parity

groups for journal volumes, etc.).
Re-establish failed pairs (Add Pair).

Planned power
outage to the
primary
storage
system

The URz pairs were temporarily suspended due
to a planned power outage to the primary
storage system.

DC8
x

No recovery procedure is required.
The primary storage system will
automatically remove the suspension
condition when the storage system is
powered on.

Universal Replicator for z/OS

®

Software Error Codes

Storage Navigator computers display an error message when an error occurs

during URz operations. The error message describes the error and displays an
error code consisting of four digits. The error message may also include a

USP V SVP error code. If you need to call the Hitachi Data Systems Support
Center for assistance, please report the URz and SVP error code(s). Please
refer to Storage Navigator Messages for a list of error codes displayed on the

Storage Navigator computers.

This manual is related to the following products: