Changing options for a journal group – HP StorageWorks XP Remote Web Console Software User Manual
Page 214
6-16
Chapter 6 Configuring Journal Groups
Hitachi Universal Replicator for IBM /OS User’s Guide
Changing Options for a Journal Group
To change options for a journal group, follow the procedure below. Both the
primary storage system administrator and the secondary storage system
administrator must perform this operation:
1. Ensure that the Storage Navigator main window is in Modify mode.
For detailed information about how to do this, please refer to Storage
Navigator User’s Guide.
2. Ensure that the Journal Operation window is displayed (see section
Changing Options for a Journal Group).
3. Do either of the following:
–
In the tree, right-click a journal group from below Registered and then
select JNL Groups and Change JNL Option from the pop-up menu.
–
In the upper-right list, right-click the desired journal group and then
select JNL Groups and Change JNL Option from the pop-up menu.
Caution
: You can select Change JNL Option only when one of the following
conditions is satisfied:
–
The attribute of the journal group is Initial.
–
The status of the journal group is Active.
–
The status of the journal group is Stop.
–
The status of the journal group is Hold.
–
The status of the journal group is Hold(Failure).
When one journal group uses multiple mirror IDs, whether you can or
cannot select Change JNL Option depends on the status of the journal
group whose mirror is not in Hold or Hold(Failure) status.
4. In the Change JNL Option window (Figure 6-5), change journal group
options and then select Set.
Caution: If the status of the journal group is Active, or if the status of the
master journal group is Hold, you can change only the Line of Speed
option.
Note
: If you have selected two or more journal groups in step 3, and want
to make some options in the Change JNL Options window unchanged, then
you must specify blank for the options. If you specify blank for an option,
the option value will remain unchanged. If you specify a value other than
blank, the specified value will be set to the selected journal groups.
5. See the Preview list in the Journal Operation window to check the settings
that you have made.
–
If you want to modify a setting, select and right-click the setting in the
Preview list and then select Modify.
–
If you want to cancel a setting, select and right-click the setting and
then select Cancel.