beautypg.com

HP StorageWorks XP Remote Web Console Software User Manual

Page 122

background image

3-56

Chapter 3 Preparing for Universal Replicator z/OS Operations

Hitachi Universal Replicator for IBM /OS User’s Guide

Data transfer speed

between hosts and

the MCU

Data transfer speed of journal volumes

Data transfer speed

between the MCU and the RCU

Time

Normal status

Temporary increase in

data to be transferred

Data transfer

speed

Figure 3-31

Data Transfer Speed with URz (Data Transfer Speed of
Journal Volumes)

As illustrated in Figure 3-31, the data transfer speed (i.e., the speed for
reading and writing) of journal volumes in the master journal group must

exceed the amount of temporary increase in data to be transferred. If the data
transfer speed of journal volumes is below the amount of temporary increase
in data to be transferred, the journal data for the temporary increase in data

to be transferred will not be stored into journal volumes timely.

In Figure 3-31, data transfer speed between the primary storage system and
the secondary storage system indicates transfer speed of journal data between

the primary storage system and the secondary storage system.

Planning RAID Group Configuration and Journal Group
Configuration

A RAID group can consist of physical volumes of different number of

revolutions, physical volumes of different capacity, and physical volumes of
different RAID configurations (e.g., RAID-1 and RAID-5). Data transfer speed

of RAID groups is affected by physical volumes and RAID configurations.

This manual is related to the following products: