Introduction 8
o
Option to disable local account access when LDAP, RADIUS, or TACACS+ authentication is
enabled
o
Increased the default VCM local user account minimum required password length
o
SNMP access security to prevent access from unauthorized management stations
•
SmartLink failover improvements
•
IGMP “NoFlood” option when IGMP snooping is enabled
•
Browser support:
o
Internet Explorer 8 and 9
o
Firefox 10 and 11
•
Firmware upgrade rollback from a previous firmware upgrade without domain deletion
•
VCEM compatibility:
o
If you are running VCEM 6.3.0 or earlier, you must upgrade to VCEM 6.3.1 or later to manage a
VC 3.70/3.75 domain. The 3.70/3.75 domain can be in a VCDG in 3.30 firmware mode or later.
To enable new features in VC 3.70/3.75, you must upgrade to VCEM 7.1.1 or later and upgrade
VC domains and VCDGs to 3.30 or later. VCEM 7.1.1 does not support VC versions prior to 3.30.
o
In VC 3.70/3.75, the telemetry port throughput is Enabled by default. You must do the following to
add a fresh VC 3.70/3.75 installation to your existing VCDG:
—
3.30-3.60 VCDG with statistics throughput disabled—Clear the Enable Throughput Statistics
checkbox on the Ethernet Settings (Advanced Settings) screen (on page
), or run the following
VCM CLI command:
set statistics-throughput Enabled=false
—
3.30-3.60 VCDG with statistics throughput enabled—Add the domain as is. No change is
required.
o
In VC 3.70/3.75, the VLAN Capacity is set to Expanded by default. You must do the following to
add a fresh VC 3.70/3.75 installation to your existing VCDG:
—
3.30-3.60 with Legacy VLAN VCDG—You cannot add the domain. Select a different VCDG.
—
3.30-3.60 with Enhanced VLAN VCDG—Add the domain as is. No change is required.
Virtual Connect documentation
The following Virtual Connect documentation is available on the Installing tab of the HP BladeSystem
Technical Resources website
•
HP Virtual Connect for c-Class BladeSystem User Guide
This guide provides details for the Virtual Connect GUI, including descriptions of screen contents and
steps to set up domains, profiles, networks, and storage.
•
HP Virtual Connect for c-Class BladeSystem Setup and Installation Guide
This guide provides hardware installation and configuration information for initial setup of a Virtual
Connect solution. The guide also provides Virtual Connect module component and LED descriptions
and guidelines for module installation and upgrades.
•
HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem User Guide
This guide provides information for using the Virtual Connect Command Line Interface, including use
scenarios and complete descriptions of all subcommands and managed elements.
- Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem