Virtual connect modules, Firmware updates – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual
Page 196

Virtual Connect modules 196
Virtual Connect modules
Firmware updates
To update firmware, use the HP BladeSystem c-Class Virtual Connect Support Utility v1.7.0. For more
information on updating the firmware, see the HP BladeSystem c-Class Virtual Connect Support Utility
documentation on the Installing tab of the HP BladeSystem Technical Resources website
Virtual Connect v3.70/3.75 does not support the HP 1/10Gb Virtual Connect Ethernet Module or the HP
1/10Gb-F Virtual Connect Ethernet Module. If your domain contains these modules, you cannot update to
VC v3.70/3.75.
To help ensure proper operation, clear the browser cache and reload the browser after firmware updates.
The firmware downgrade process has changed with VC v3.70/3.75 and VCSU v1.7.0. The following table
describes the circumstances under downgrading VC firmware requires deletion of the domain.
Upgrade to and
downgrade from
VC 1.xx
VC 2.xx
VC 3.0x
VC
3.10-3.15
VC
3.17-3.60
VC
3.70-3.75
VC 1.xx
Delete
domain
Delete
domain
Delete
domain
Delete
domain
Delete
domain
Delete
domain
VC 2.xx
—
Delete
domain
Delete
domain
Delete
domain
Delete
domain
Delete
domain
VC 3.0x
—
—
Delete
domain
Delete
domain
Delete
domain
Delete
domain
VC 3.10-3.15
—
—
—
Delete
domain
Delete
domain
Delete
domain
VC 3.17-3.60
—
—
—
—
Delete
domain
Firmware
rollback
Domain deletion is not required when a firmware downgrade is performed to a firmware version that existed
prior to the firmware upgrade. However, if no previous firmware upgrade has been performed,
downgrading without domain deletion is not allowed. When attempting a firmware downgrade, consider
the following:
•
Multiple, consecutive firmware downgrades are not supported.
•
A same version upgrade does not prevent a future downgrade if you decide to downgrade to the
previous version in the future.
•
You can perform a firmware downgrade only to a version that was installed on the primary VC module
prior to the upgrade.
•
The VCM configuration, module types, and cabling configuration must be the same before and after the
upgrade.
•
The VCM credentials must be the same before and after the upgrade.
- Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem