HP XP P9500 Storage User Manual
Page 67
Table 10 RAID Manager Error Codes (continued)
Description
SSB2 code
The volume you specified as a P-VOL was a Cnt Ac-S P-VOL. The reverse copy or the quick restore
operation was rejected because the Cnt Ac-S pair was not suspended (PSUE status) or split (PSUS
status).
235B
The volume you specified as a P-VOL was a Cnt Ac-S S-VOL. Because the Cnt Ac-S pair was not
suspended (PSUE status) or split (PSUS status), the reverse copy or the Quick Restore operation was
rejected.
235C
The volume you specified as an S-VOL was a Cnt Ac-S P-VOL. The reverse copy or the quick restore
operation was rejected because the Cnt Ac-S pair was not suspended (PSUE status) or split (PSUS
status).
235D
The reverse copy or the quick restore operation was rejected because the volume you specified as
the P-VOL has the S-VOL Disable attribute assigned by the Data Retention.
236C
The pair operation was rejected because the volume you specified as the S-VOL has the S-VOL Disable
attribute assigned by the Data Retention, the pair operation was rejected.
236D
The pair operation was rejected because the volume you specified as the P-VOL was not mounted,
the pair operation was rejected.
2370
The pair operation was rejected because the volume you specified as the P-VOL was blocked or a
system disk.
2371
The pair operation was rejected because the volume you specified as the P-VOL was being formatted.
2372
The pair operation was rejected because the volume you specified as the P-VOL was a command
device.
2373
The pair operation was rejected for one of the following reasons:
2380
•
The volume you specified as the S-VOL was not mounted.
•
The MU number was 3 or more.
The pair operation was rejected because the volume you specified as the S-VOL was blocked or a
system disk.
2381
The pair operation was rejected because the volume you specified as the S-VOL was being formatted.
2382
The pair operation was rejected because the volume you specified as the S-VOL was a command
device.
2383
The pair operation was rejected because the volume you specified as the P-VOL was a reserved volume
for Auto LUN.
2385
The pair operation was rejected because the volume you specified as the S-VOL was a reserved
volume for Auto LUN.
2386
The create pair operation was rejected because the volume you specified as the P-VOL was the volume
for Auto LUN.
2387
The registering of the pair in the consistency group was rejected because the number of the pairs in
a consistency group exceeded the definable maximum number of pairs.
2394
The pair operation was rejected because the pair sharing the volume you specified as the P-VOL was
undergoing the reverse copy operation or the Quick Restore operation.
2395
The pair operation was rejected because the L1 pair sharing the P-VOL you specified as the root
volume was undergoing the reverse copy operation or the Quick Restore operation.
2396
The pair operation was rejected because the L2 pair sharing the P-VOL or S-VOL you specified as the
node volume was undergoing the reverse copy operation or the Quick Restore operation.
2397
The quick restore or reverse copy operation was rejected because the pair you specified was not
suspended (PSUE status) or split (PSUS status).
2398
The quick restore or reverse copy operation was rejected because some of the pairs sharing the volume
you specified as the P-VOL were not suspended (PSUE status) or split (PSUS status).
2399
Troubleshooting with RAID Manager
67