beautypg.com

HP XP P9500 Storage User Manual

Page 65

background image

Table 10 RAID Manager Error Codes (continued)

Description

SSB2 code

The consistency group pair-split was rejected because some of the pairs in the consistency group
were being resynchronized, split, or were already suspended.

The pair operation was rejected because the pair status of the P-VOL, the S-VOL, or both showed
that the pair could not receive the issued command.

The pair operation was rejected because the volume you specified as the S-VOL was online to the
host.

2312

The create pair operation was rejected because the volume you specified as the S-VOL was the S-VOL
of another pair that was split (PSUS status).

2314

The quick restore or reverse copy operation was rejected because the P-VOL of the pair you specified
was online to the host.

231F

The pair operation was rejected because the necessary shared memory was not installed, or
initialization was not completed.

2322

The pair operation was rejected because the number of slots of the volume you specified as the P-VOL
exceeded the upper limit.

2324

The pair operation was rejected because the number of slots of the volume you specified as the S-VOL
exceeded the upper limit.

2325

The create pair operation was rejected because the volume you specified as the P-VOL had already
had three S-VOLs.

2326

The create pair operation was rejected because the node volume specified as the P-VOL had already
had two S-VOLs.

2327

The pair operation was rejected because the pair configuration exceeded the number of the layers
of the cascade configuration.

2328

The pair operation was rejected because the volume you specified as the S-VOL was the S-VOL of an
existing pair.

2329

The create pair operation was rejected because pairs that would exceed the license capacity were
going to be created.

232A

The pair operation was rejected because the volume you specified as the P-VOL was allocated as the
destination of the Auto LUN.

232F

The pair operation was rejected due to one of the following causes.

2331

The volume you specified as the P-VOL was a reserved volume.

The volume you specified as the P-VOL was the volume for Auto LUN.

The capacity of the P-VOL and the S-VOL you specified was not the same.

The create pair operation was rejected because the volume you specified as the P-VOL had already
had three S-VOLs.

2332

The pair operation was rejected because the volume you specified as the P-VOL was not the P-VOL
of the existing pair.

2333

One of the following occurred:

2334

The pair operation was rejected because the volume you specified as the P-VOL had an emulation
type that could not be handled by RAID Manager.

The consistency group pair-split was rejected because the volume you specified as the P-VOL was
an intermediate volume.

The pair operation was rejected because the volume you specified as the S-VOL had an emulation
type that could not be handled by RAID Manager.

2335

The pair operation was rejected because the emulation type for the P-VOL you specified was different
from the emulation type of the S-VOL.

2336

Troubleshooting with RAID Manager

65