Table 10 RAID Manager Error Codes (continued)
Description
SSB2 code
The consistency group pair-split was rejected because the Cnt Ac-J pair was not in PAIR status, split
(PSUS status), or suspended (PSUE status). The Cnt Ac-J S-VOL was the BC P-VOL included in the
consistency group on which the consistency group pair-split was performed.
201B
The quick restore operation was rejected because the cache mode of the P-VOL you specified was
different from the cache mode of the external S-VOL.
2026
The pair operation was rejected because the volume you specified as a P-VOL was a quorum disk.
2036
The pair operation was rejected because the volume you specified as an S-VOL was a quorum disk.
2037
The volume you specified as a P-VOL was a volume using two mirrors included in the 3-Cnt Ac-J DC
multi-target, cascade, or delta resync configuration. The operation was rejected because the volume
was used in the delta resync pair or as a Cnt Ac-J pair volume.
2043
The volume you specified as an S-VOL was a volume using two mirrors included in the 3-Cnt Ac-J DC
multi-target, cascade, or delta resync configuration. The operation was rejected because the volume
was used in the delta resync pair or as a Cnt Ac-J pair volume.
2044
The pair operation was rejected because the current microcode version does not support the P-VOL
capacity you specified.
2047
The pair operation was rejected because the current microcode version does not support the S-VOL
capacity you specified.
2048
The Paircreate operation was rejected because the MU number you specified was in use.
205B
The volume you specified as a P-VOL was a volume of a Cnt Ac-J pair. The pair operation was rejected
because the status of the Cnt Ac-J pair was invalid.
2060
The volume you specified as an S-VOL was a volume of a Cnt Ac-J pair. The pair operation was
rejected because the status of the Cnt Ac-J pair was invalid.
2061
The volumes you specified for the pair were shared by Cnt Ac-S and Cnt Ac-J. The quick restore or
reverse copy operation was rejected because the Cnt Ac-S or Cnt Ac-J pair was not split (PSUS status).
2067
The pair operation was rejected because the P-VOL or S-VOL you specified was being shredded.
2068
The pair operation was rejected for one of the following reasons:
2072
•
The P-VOL was also a FS or SS pool volume.
•
The P-VOL was also a FS or SS secondary volume, or V-VOL.
•
The P-VOL was also a FS or SS P-VOL, and one of the following conditions was also true.
- While the FS or SS pair was restored, the create, split, or resync pair operation was performed
on the BC pair.
- The BC quick restore operation was performed.
- A consistency group was defined for BC.
- After the MU number used by a FS or SS pair was specified, the create, split, or resync pair
operation was performed on the BC pair.
The pair operation was rejected for one of the following reasons:
2073
•
The S-VOL was also an FS or SS pool volume.
•
The S-VOL was also an FS or SS secondary volume, or V-VOL.
•
The S-VOL was an FS or SS S-VOL pair, and one of the following conditions was also true.
- The FS or SS pair was being restored.
- The BC quick restore operation was performed.
- A create pair operation was performed on the BC pair.
62