HP XP P9500 Storage User Manual
Page 404
Return
Code
Explanation
1002
Details
There is no path on which the operation can be performed.
Action
Refresh the host information, check the path status, and then
perform the operation again.
1003
Details
No path was detected.
Action
Check whether a path between the host and the storage system is
connected. If a path is connected, check whether HDLM is configured
correctly.
1004
Details
Memory required for HDLM internal processing could not be allocated.
Action
Terminate unnecessary applications to increase free memory, or
restart the host.
1006
Details
An Offline path cannot be placed Online.
Action
Remove the error in the path, and then retry.
1007
Details
The target path of the offline operation is the last, remaining path
connected to the device and therefore, cannot be placed in the offline
status.
Action
Click Refresh to update the host information, check the path status,
and then retry the offline operation.
1015
Details
The Offline path cannot be placed Online.
Action
Remove the error in the path, and then retry.
1016
Details
The target path(s) are already Online.
Action
Update the host information, and then check the path status.
1017
Details
The target path(s) are already Offline(C).
Action
Update the host information, and then check the path status.
1019
Details
An error occurred during HDLM internal processing.
8-112
Messages