HP StorageWorks EVA Controller HSG V8.8 Software User Manual
Page 65

Interpreting Agent Email Messages
65
Command Console V2.5 User Guide
The details about the failure of the LUN follow in parentheses, in the format:
virtual_disk:state
where
virtual_disk
is the unit number of the virtual disk and
state
is any of the
following:
0—Good.
1—Reduced.
2—Reconstructing.
3—Failed.
In this example, logical unit D100 failed.
In most cases, the RaidManager sends at least two consecutive email messages.
The first message is always in the form:
---------------
From RaidManager Tue Oct 6 16:09:37 1998
Date: Tue, 6 Oct 1998 16:09:37 -0500 (EST)
From: RaidManager
This is an automatic message from your StorageWorks
RAID Agent, steamd. The following message was just received.
Please check your syslog files and RAID box!
Hostname: Suncity
WARNING: - A RAID system change has been detected: Suncity HSG80
OVRL=1 (SP_MONITOR: MonitorSubsys)
End Of Automatic Message.
-------------
The text of the second message will be similar to the following (depending on the
error):
---------
From RaidManager Tue Oct 6 16:09:37 1998
Date: Tue, 6 Oct 1998 16:09:37 -0500 (EST)
From: RaidManager
This is an automatic message from your StorageWorks
RAID Agent, steamd. The following message was just received.
Please check your syslog files and RAID box!
Hostname: Suncity
WARNING: - Suncity HSG80 12000000000 HSG80 disks(disk10200:1
disk10300:2) (SP_MONITOR: MonitorSubsys)
End Of Automatic Message.
-------------