HP ProLiant DL145 G3 Server User Manual
Page 44

Using LO100 44
o
On ProLiant ML110 G4 servers, verify or change the following settings:
Configure Console Redirection
—
Console Redirection—Enabled
—
EMC Support (SPCR)—Enabled
—
Flow Control—None
—
Redirection After BIOS POST—Always
—
Terminal Type—VT100
—
Sredir Memory Display Delay—No Delay
I/O Device Configuration—Configure IO Port
—
Serial Port 1 Address—3F8/IRQ4
o
On ProLiant ML115 G1 servers, verify or change the following settings:
Configure Console Redirection
—
Console Redirection—Enabled
—
EMS Support (SPCR)—Enabled
—
Flow Control—None
—
Redirection After BIOS POST—Always
—
Terminal Type—VT100
—
Sredir Memory Display Delay—No Delay
I/O Device Configuration-Configure IO Port
—
Serial Port 1 Address—3F8/IRQ4
o
On ProLiant DL140 G3 and ProLiant DL145 G3 servers, verify or change the following settings:
Console Redirection
—
Console Redirection—Enabled
—
EMS Console—Enabled
—
Baud Rate—115.2K
—
Console Type—VT100+
—
Flow Control—None
—
Continue C.R. after POST—Enabled
I/O Device
—
Serial Port Mode—BMC
—
Serial Port A—Enabled
—
Base I/O address—3F8
—
Interrupt—IRQ 4
o
On ProLiant ML150 G3 servers, verify or change the following settings:
Console Redirection
—
BIOS Serial console—Enabled
—
EMC Support (SPCR)—Enabled