Controlling server power through the clp, Monitoring sensors, Viewing sensor data from a web browser – HP ProLiant DL145 G3 Server User Manual
Page 29

Using LO100 29
Controlling server power through the CLP
1.
Log in to LO100 CLP as described in the "Logging in to LO100 (on page
2.
Change to the system1 target by entering cd system1.
3.
To power on the server, enter start /system1. For example:
/./system1/> start /system1
System1 started.
4.
To power off the server, enter stop /system1. For example:
/./system1/> stop /system1
System1 stopped.
The -force option can also be used with the stop command. This option forces the
implementation to stop the target, ignoring any policy that might cause the implementation to
normally not execute the command. In remote management processor implementation, this process is
equivalent to a hard power down.
5.
To reset the server, enter reset /system1. For example:
/./system1/> reset
System1 reset.
Monitoring sensors
LO100 provides operating system-independent remote monitoring of the current status of major sensors of
a target server including system temperature, fans, and voltage. You can view the data for this feature on
the Monitoring Sensors Page through a web browser or through the BIOS Setup Utility.
Viewing sensor data from a web browser
The Monitoring Sensors screen displays a snapshot of the temperature, fans, and voltage sensor data,
including sensor type, name, status, and current reading. To access this page from a web browser, on the
main menu navigation bar, click Monitoring Sensor.
To update the display, click the Refresh button. To view or add a PEF action, click PEF. For more
information, see "Platform Event Filtering configuration (on page
)."