Page 31
Using LO100 31
Initially, there are no entries are in the Current PEF Entries section because no PEFs are defined. When
PEF entries are defined, the PEF Control field is active and enables you to set the individual entries to
enabled, disabled, or deleted.
To configure an action (PEF entry), select the desired Event Offsets, select the desired PEF Action settings,
and then click Add.
•
Event Offsets—Are trip points (movements across thresholds) that define what type of sensor event
triggers an action. The information in the Events Offsets section varies with the type of sensor. Not all
options are available for all sensors. You can select any of the available options.
•
PEF Action—Displays the same information for all sensors:
o
Sensor Type—Displays the type of sensor selected.
o
Sensor Name—Displays the name of the sensor.
o
PEF Action—Enables you to select from Power Off, Power Cycle, Hard Reset, and Send Alert
(requires a systems management console supporting IPMI 1.5 or later).
o
PEF Control—Enables or disables the sensor.
o
Alert Policy (list adjacent to the Add button)—Enables you to select an alert policy (if defined).
Alert policies are defined on the PET Configuration screen. For information, see "Platform event
trap configuration (on page
If alert policies are not defined (default), the Alert Policy list displays No Alert Policy. The Alert
Policy list populates after alert policies are defined and configured. After configuring your alert
policies, you can select from the defined alert policies for this sensor and PEF.
o
Add—Adds the new entry to the PEF Current Entry table at the top of the page.