3. Calibration process

a) Press the

key

Maintenance screen is

displayed again

b) Press <1> key

Zero Calibration screen is

displayed

c) Verify that the hopper is completely empty

(see sec. 5.2). During calibration process the

automatic feeling of the hopper is prevented.

d) Wait for stabilization of IC parameter - the sign becomes dark

and press <ENT>,to begin Offset calibration

"Please Wait" screen is displayed (remaining

time is displayed), showing the calculated "IC"

(Internal counting) Offset Factor.

If the "IC" is too low (

should be ≥200) – an

alarm "Cal Error Offset Too Low" is displayed

Reasons could be:

The Load cell Protection devised has not

been released (see Appendix A)

The Load cell is defective (replace it)

The controller is defective (consult your superior)

e) After a few seconds (If the "IC" is O.K.)

"GAIN Calibration" screen is displayed

f) Press

g) Enter or modify the Test Weight value

h) Press to make the new value valid

i) Enter a standard Calibration test weight, in the range of 1,000 - 2,500g., into the

hopper

j) Wait for stabilization of IC parameter (the sign becomes dark), and then press

to start GAIN calibration.

k) "Please Wait" screen is displayed again

(remaining time is indicated)