4 emptying / refilling the feeding screw – Sterlco SF1000 Gravimetric Additive Feeder User Manual

Page 25

background image

25

5.4 Emptying / Refilling the feeding screw


 While in Main Screen press

key

Fill/Empty Screw screen will be displayed

 Press

key to fill the screw - the motor will

rotate at 50% speed for 5 seconds, filling the
screw (recommended after replacing or
cleaning screw)

 Press

key to empty the screw - the motor will rotate in opposite direction at 50%

speed for 5 seconds, emptying the screw

 Press again, to repeat the turning cycle each time, or

Press to return to Main screen

5.5 Moving feeder to another injection machine or replacing controller


The same feeder can easily be used with several injection machines, provided that each
machine is equipped with its own neckpiece adapter.

To move the feeder (without the neckpiece) from one injection machine to another:

a) Remove the feeder from the neckpiece by releasing its two quick release star knobs.

b) Install the feeder on the new injection machine.

c) Repeat static calibration procedure (also when a new controller is installed).