beautypg.com

Gdl-t difference screen, Gdl-t summary screen – Dwyer GDL-T User Manual

Page 29

background image

DwyerLog User’s Guide

Version 1.4x

29/33

if the alarm condition goes away. See the Alarm Setup section in the Software User's Guide for more
information on setting and using alarms.

GDL-T Difference Screen

When four channels are selected to log, or when the GDL-T is idle, the unit will display an additional temperature
difference screen. The temperature difference is always displayed between the Internal Channel (Temp Int) and
Channel 1 (Temp 1), and between Channel 2 (Temp 2) and Channel 3 (Temp 3).

When less than four channels are selected to log, the temperature difference will be displayed on the sample screen.

GDL-T Summary Screen

The Summary screen is shown below.

The icons in the summary screen are identical to the icons in the Sample screen. The Summary screen shows:

• The User Information: This 30 character text field is entered through the DwyerLog setup software, and

can be any text that describes the logger

Logging Rate: Is the rate at which the data in memory was logged at.
Samples: Shows the number of samples stored in memory. If a rollover has occurred this number will

show the maximum number of samples that can be stored in the logger, and will not change, even though
the logger may be logging.

Mem Used: Shows the length (in days, hours, minutes or seconds) of data currently stored in memory. If a

rollover has occurred, this number will show the maximum length of data that can be stored in memory, for
a given sample rate. If a rollover has occurred, this number will not change even though the logger may be
logging.

Mem Left: Shows the length (in days, hours, minutes or seconds) of data the logger can record without

overwriting currently recorded data (record without a rollover). If a rollover has occurred, this number will
show 0 Sec, even though the logger may still be logging.