Dwyer GFM4 User Manual
Page 17
Indication
Kgain [2]
Kgain [3]
Kgain [4]
Kgain [5]
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
KfactorMode
TmpAlarmMode
LowAlarmC
HiAlarmC
PrsAlarmMode
LowAlarmP
HiAlarmP
Zero_T
Tcor_K
No.
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
Data Type
float
float
float
float
float
float
float
float
float
float
char
char
float
float
char
float
float
float
float
Notes
Gain for DRC Lag Constant [Do Not Alter]
Gain for DRC Lag Constant [Do Not Alter]
Gain for DRC Lag Constant [Do Not Alter]
Gain for DRC Lag Constant [Do Not Alter]
K-Factor Mode: D-Dis’d, I-Internal, U-User Def’d
Temp. Alarm Mode [‘R’ - Enabled, ‘S’ - Disabled]
Low Temp. Alarm Setting [0 to 50°C]
High Temp. Alarm Setting [0 to 50°C]
Press Alarm Mode [‘R’ - Enabled, ‘S’ - Disabled]
Low Press. Alarm Setting [0 to 100 PSI]
High Press. Alarm Setting [0 to 100 PSI]
Resistance when last AutoZero was done [Counts]
Resistance correction coeffecient [PFS/count]
Name
GasIndentifier
FullScaleRange
StdTemp
StdPressure
StdDensity
CalibrationGas
CalibratedBy
CalibratedAt
DateCalibrated
DateCalibrationDue
PID_Kp
PID_Ki
PID_Kd
SensorTbl[0][Sensor Value]
SensorTbl[0][Flow]
SensorTbl[1][Sensor Value]
SensorTbl[1][Flow]
SensorTbl[2][Sensor Value]
SensorTbl[2][Flow]
SensorTbl[3][Sensor Value]
SensorTbl[3][Flow]
SensorTbl[4][Sensor Value]
SensorTbl[4][Flow]
SensorTbl[5][Sensor Value]
SensorTbl[5][Flow]
SensorTbl[6][Sensor Value]
SensorTbl[6][Flow]
SensorTbl[7][Sensor Value]
SensorTbl[7][Flow]
SensorTbl[8][Sensor Value]
SensorTbl[8][Flow]
SensorTbl[9][Sensor Value]
SensorTbl[9][Flow]
SensorTbl[10][Sensor Value]
SensorTbl[10][Flow]
Index
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
Data Type
char[27]
float
float
float
float
char[27]
char[20]
char[20]
char[10]
char[10]
float
float
float
uint
float
uint
float
uint
float
uint
float
uint
float
uint
float
uint
float
uint
float
uint
float
uint
float
uint
float
Notes
Name of Gas [If not calibrated = ‘Uncalibrated’]
Full Scale Range in SLPM
Standard Temperature
Standard Pressure
Gas Standard Density
Name of Gas used for Calibration
[If not calibrated = ‘Uncalibrated’]
Name of person who performed actual calibration
Name of Calibration Facility
Calibration Date
Date Calibration Due
Reserved
Reserved
Reserved
Index 0: Must be 120 (zero value) Do not Alter!
Index 0: Must be 0.0 (zero PFS) Do not Alter!
10.0% FS A/D Value from Sensor [counts]
Actual Flow in PFS [0.1]
20.0% FS A/D Value from Sensor [counts]
Actual Flow in PFS [0.2]
30.0% FS A/D Value from Sensor [counts]
Actual Flow in PFS [0.3]
40.0% FS A/D Value from Sensor [counts]
Actual Flow in PFS [0.4]
50.0% FS A/D Value from Sensor [counts]
Actual Flow in PFS [0.5]
60.0% FS A/D Value from Sensor [counts]
Actual Flow in PFS [0.6]
70.0% FS A/D Value from Sensor [counts]
Actual Flow in PFS [0.7]
80.0% FS A/D Value from Sensor [counts]
Actual Flow in PFS [0.8]
90.0% FS A/D Value from Sensor [counts]
Actual Flow in PFS [0.9]
100.0% FS A/D Value from Sensor [counts]
Flow in PFS. Should be 1.0. Do not Alter!
Calibration Table
Gas Dependent Variables
Note: Values will be available for selected gas only.
Page 17