Requesting interval history manually – Badger Meter ORION AMR/AMI Hardware Solutions for Gas Utilities User Manual
Page 61
Requesting Interval History Manually
If it was not requested as an automatic work item, you can manually initiate a request for historical data from an ORION
Migratable or ORION Fixed Network (in mobile mode) endpoint by performing the following steps
1 With the Current Reading tab selected on
the Service Details screen, click the Interval
History tab
OTEE:
N
“Not Required/Optional” displays at the
top of the screen to indicate that an
automatic work item was not requested
The ”Days“ option buttons become active when
the mobile transceiver receives the mobile
message from the endpoint
2 Select the button for the number of days:
7 Days, 14 Days, 30 Days, 60 Days, or All For
additional information, see
Figure 65: Interval History tab without work items
Result: The Test Circle Selection screen displays with
the Meter Type selected.
OTEE:
N
This screen does not display for
Permalog meters since they have only
one test circle
3 Select the units of Measure and Test Circle Then
click the Select button
Result: The Test Circle Selection screen closes,
the message at the top of the screen changes to
"Requested" and the interval data is extracted. This
may take a few seconds.
Figure 66: Test Circle Selection screen
The message changes to "Action Complete" and the
data is extracted and displayed in the fields. Any
exception status information, such as tamper or
potential leak, also displays.
Interval: The number of minutes, 60 or 15,
between readings
Date Range: The start and end date and time of
the profile data extracted, based on the selection
OTEE:
N
ORS uses universal time (UTC) which is
converted to local time in the reading
data management software
Figure 67: Interval History results
Total Consumption: Usage for the selected time period fills in this field
Exception Status Found: Any alerts or exception status indicators are listed in this field In Figure 67, "Programming"
means the endpoint settings were changed via IR
The data collected is saved and transferred back to the reading data management software operator as part of the route
unload file For more information, refer to
"Historical Interval data" on page 60
TWO-WAy COMMuNICATIONS
Page 61
April 2014
ORION® Meter Reading System (ORS)