SERVICE DETAILS
The Service Details screen displays all of the information stored in ORS for each account You can view the details for the
customer, enter codes, messages and manual meter readings You can also access the two-way communication functionality
for ORION Migratable and Fixed Network (in mobile mode) endpoints
Access the Service Details screen by clicking the Details button next to the account line item in List View
OTEE:
N
The Service Details screen is also available when performing a Quick Read
The Service Details screen has two tabs: Current Reading and Comment Codes/Messages
Figure 26: Service details screen – Reading from ORION Me endpoint
Current Reading
The Current Reading tab of the Service Details screen displays the current meter reading, date and time along with meter
information from the reading data management software The type of endpoint technology is displayed in the upper right
corner of the screen
Account Number
Indicates the account number from the reading data management software
Service Type
Describes the service type being measured by the meter, such as water, electric, gas, etc
Module S/N
The serial number of the ORION endpoint assigned to the meter The serial number allows ORS
to uniquely identify each meter The serial number is sent from the reading data management
software and is cannot be changed
The Actual Read Method, Read date/Time and Reader Id are displayed below the Module S/N
Current Reading
The current reading value is displayed in this field If the meter is a gas meter, the index value
displays instead of the subcount
•
Unread
If the meter is not read, the word “Unread” appears in the reading field
•
Low Reading
If the current reading is lower than this value, it will be considered low
“Low Read” displays below the reading
•
High Reading
If the current reading is higher than this value, it will be considered high
“High Read” displays below the reading
•
Potential Leak
If the ORION endpoint detects a potential water leak, “Pot Leak” displays
below the reading See Figure 27 on the next page