GENERAL

Housing

Material:

Makrolon 9415
flame-retardant

Flammability class:

UL 94 VO, self-extinguishing

Plug-in module, inserted from the front

Safety test

Complies with EN 61010-1 (VDE 0411-1):
Overvoltage category II
Contamination class 2
Working voltage range 300 V
Protection class II

Certifications

Type tested to EN 14597 (replaces DIN
3440)

With certified sensors applicable for:

w

Heat generating plants with outflow
temperatures up to 120°C to DIN 4751

w

Hot-water plants with outflow temperatures
above 110°C to DIN 4752

w

Thermal transfer plants with organic transfer
media to DIN 4754

w

Oil-heated plants to DIN 4755

cULus-certification

(Type 1, indoor use)
File: E 208286

Electrical connections

Flat-pin connectors 1 x 6,3 mm or 2 x 2,8 mm
to DIN 46 244

Mounting

Panel mounting with two fixing clamps at
top/bottom or right/left,
High-density mounting possible

Mounting position: uncritical
Weight:

0,27kg

Accessories delivered with the unit

Operating manual
Fixing clamps

KS40-1 burner