Pyromation Series 642 User Manual
Page 37
Series 642
Technical data
Pyromation, Inc.
37
9.0.5
Environment
Ambient temperature limits
• Without display: -40 to +85 °C (-40 °F to +185 °F)
• With display:
-40 to +80 °C (-40 °F to +176 °F)
For use in hazardous areas, see Ex certificate
Storage temperature
• Without display: -40 to +100 °C (-40 °F to +212 °F)
• With display:
-40 to +85 °C (-40 °F to +185 °F)
Operating height
Up to 2000 m above MSL
Climate class
As per EN 60 654-1, Class C
Degree of protection
IP 67, NEMA 4x
Shock and vibration resistance
3g / 2 to 150 Hz as per IEC 60 068-2-6
Electromagnetic compatibility
(EMC)
Interference immunity and interference emission as per EN 61 326-1 (IEC 1326) and NAMUR NE
21
0.08...2 GHz 10 V/m; 1.4...2 GHz 30 V/m to EN 61000-4-3
Condensation
Permitted
Installation category
I
Pollution degree
2
At temperatures < -4 °F (-20 °C) the display may react slowly. Readability of the display
cannot be guaranteed at temperatures < -30 °C (-22 °F).