6

Installation

The 2100 meets NEMA 4X/IP65 requirements for indoor use when properly

installed. The unit is intended to be mounted into an enclosed panel. Prepare the
panel cutout to the dimensions shown. Remove the panel latch from the unit.

Slide the panel gasket over the rear of

the unit to the back of the bezel.

The unit should be installed

fully assembled. Insert the

unit into the panel cutout.

While holding the unit in place, push the panel latch over the rear of the unit

so that the tabs of the panel latch engage in the slots on the case. The panel latch
should be engaged in the farthest forward slot possible. To achieve a proper seal,
tighten the latch screws evenly until the unit is snug in the panel (Torque to
approximately 7 in-lbs [79N-cm]). Do not over-tighten the screws.

Installation Environment

The unit should be installed in a location that does not exceed the maximum

operating temperature and provides good air circulation. Placing the unit near
devices that generate excessive heat should be avoided.

The bezel should be cleaned only with a soft cloth and neutral soap product.

Do NOT use solvents. Continuous exposure to direct sunlight may accelerate the
aging process of the bezel.

Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to operate the

keypad of the unit.

PANEL CUT-OUT

1.0 I

NSTALLING THE

M

ETER

2.0 S

ETTING THE

J

UMPERS

The meter has three jumpers that must be checked and/or changed prior to

applying power. The following Jumper Selection Figures show an enlargement
of the jumper area.

To access the jumpers, remove the meter base from the case by firmly

squeezing and pulling back on the side rear finger tabs. This should lower the
latch below the case slot (which is located just in front of the finger tabs). It is
recommended to release the latch on one side, then start the other side latch.

Input Jumpers

These jumpers are used to select the proper input types, Voltage (V) or Current

(I). The input type selected in programming must match the jumper setting. See
the Jumper Selection Figures for more details.

User Input Logic Jumper

This jumper selects the logic state of all the user inputs. If the user inputs are

not used, it is not necessary to check or move this jumper.

Jumper Selection

JUMPER SELECTIONS

The

indicates factory setting.

REAR TERMINALS

(CURRENT) I

FRONT DISPLAY

INPUT JUMPER LOCATIONS

USER INPUT
JUMPER
LOCATION

(VOLTAGE) V

INPUT A

INPUT B

V

I

Note: The jumper position is designated on the printed circuit board with the

text enclosed in parenthesis.