RESET MINIMUM
r-Lo
F1
When activated (momentary action),
rESEt
flashes and the Minimum reading
is set to the present assigned value. The Minimum function then continues from
that value. This selection functions independent of the selected display.
r-Lo
USr-1
r-HL
USr-1
r-HL
F1
RESET MAXIMUM AND MINIMUM
When activated (momentary action),
rESEt
flashes and the Maximum and
Minimum readings are set to the present assigned values. The Maximum and
Minimum function then continues from that value. This selection functions
independent of the selected display.
d-LEV
USr-1
d-LEV
F1
CHANGE DISPLAY INTENSITY LEVEL
When activated (momentary action), the display intensity changes to the next
intensity level (of 4). The four levels correspond to Display Intensity Level (
d-
LEv
) settings of 0, 3, 8, and 15.
Note: Following display functions are only available on User Input.
dISP
Usr-1
ADVANCE DISPLAY
When activated (momentary action), the display advances to the next display
that is not locked out from the Display Mode.
dSP-a
Usr-1
SELECT DISPLAY A
When activated (momentary action), the display advances to Display A,
if enabled.
dSP-b
USr-1
SELECT DISPLAY B
When activated (momentary action), the display advances to Display B,
if enabled.
dSP-C
Usr-1
SELECT DISPLAY C
When activated (momentary action), the display advances to Display C,
if enabled.
dSP-_
Usr-1
SELECT DISPLAY _
When activated (momentary action), the display advances to the Display _
(no annunciator), if enabled.
LISt
USr-1
LISt
F1
EXCHANGE PARAMETER LISTS
Two lists of values are available for
SP-1
,
SP-2
,
SP-3
,
SP-4
. The two lists are
named
LSt-A
and
LSt-b
. If a user input is used to select the list then
LSt-A
is
selected when the user input is not active and and
LSt-b
is selected when the
user input is active (maintained action). If a front panel key is used to select the
list then the list will toggle for each key press (momentary action). The display
will only indicate which list is active when the list is changed.
To program the values for
LSt-A
and
LSt-b
, first complete the programming
of all the parameters. Exit programming and switch to the other list. Re-enter
programming and enter the values for
SP-1
,
SP-2
,
SP-3
,
SP-4
. If any other
parameters are changed then the other list values must be reprogrammed.
SETPOINT SELECTIONS
LISt
-
Select main or alternate setpoints
r-1
-
Reset Setpoint 1 (Alarm 1)
r-2
-
Reset Setpoint 2 (Alarm 2)
r-3
-
Reset Setpoint 3 (Alarm 3)
r-4
-
Reset Setpoint 4 (Alarm 4)
r-34
-
Reset Setpoint 3 & 4 (Alarm 3 & 4)
r-234
-
Reset Setpoint 2, 3 & 4 (Alarm 2, 3 & 4)
r-ALL
-
Reset Setpoint All (Alarm All)
The following selections are functional only with the Setpoint plug-in card
installed. Refer to the Setpoint Card Bulletin shipped with the Setpoint plug-in
card for an explanation of their operation.
⎧
⎨
⎩
Setpoint
Card
Only
USr-1
F1
PRINT REQUEST
The meter issues a block print through the serial port when activated, and the
serial type is set to
rLC
. The data transmitted during a print request and the serial
type is programmed in Module 7. If the user input is still active after the
transmission is complete (about 100 msec), an additional transmission occurs.
As long as the user input is held active, continuous transmissions occur.