NOSHOK 2100 Series Field Upgradeable Dual Input Process Indicator User Manual
Page 23
23
REGISTER
ADDRESS
1
REGISTER NAME
LOW LIMIT
2
HIGH LIMIT
2
FACTORY
SETTING
ACCESS
COMMENTS
CH A
CH B
SEE MODULE 1 FOR DESCRIPTION OF PARAMETERS
INPUT PARAMETERS
40105
40101
40205
40201
Digital Input Filter
Input Range
0
0
250
1
10
0
Read/Write
Read/Write
40106
40102
40206
40202
0
0
250
6
10
3
Read/Write
Read/Write
1=1 display unit
0=5.3, 1=7.5, 2=16.7, 3=19.8, 4=20, 5=30, 6=105
40107
40103
40207
40203
Number of Scaling Points
Decimal Point
2
0
16
4
2
3
Read/Write
Read/Write
Number of LInearization Scaling Points
0=0, 1=0.0, 2=0.00, 3=0.000, 4=0.0000
40108
40104
40208
40204
Reserved
Rounding Factor
N/A
0
N/A
6
N/A
0
N/A
Read/Write
0=1, 1=2, 2=5, 3=10, 4=20, 5=50, 6=100
SCALING POINTS PARAMETERS
40171
40169
40111
40109
40271
40269
40211
40209
Input 16 Input Value (Hi word)
Input 16 Input Value (Hi word)
Display 1 Input Value (Hi word)
Input 1 Input Value (Hi word)
-19999
-19999
-19999
-19999
99999
99999
99999
99999
0
0
0
0
Read/Write
Read/Write
Read/Write
Read/Write
1=0.001
1=0.001
thru
40172
40170
40112
40110
thru
40272
40270
40212
40210
Input 16 Input Value (Lo word)
Input 16 Input Value (Lo word)
Display 1 Input Value (Lo word)
Input 1 Input Value (Lo word)
...
...
...
...
SEE MODULE 2 FOR DESCRIPTIONS OF PARAMETERS
USER INPUT/FUNCTION KEYS
40301
User Input 1 Action
0
30
0
Read/Write
40302
User Input 2 Action
0
30
0
Read/Write
40321
40320
40032*
40030*
40318
40319
40031*
40029*
40317
40316
40314
40307
40312
40305
40315
40313
40306
40311
40304
40303
Program Mode Security Code
SP4 Quick Pro
Input B Offset Value (Lo word)
Input A Offset Value (Lo word)
SP2 Quick Pro
SP3 Quick Pro
Input B Offset Value (Hi word)
Input A Offset Value (Hi word)
SP1 Quick Pro
SECONDARY PARAMETERS
Total Display
Maximum (Hi) Value
User F2 Second Action
Input B Display
User Reset Key Action
Minimum (Lo) Value
Calculation Display
User F1 Second Action
Input A Display Lock
User F2 Key Action
User F1 Key Action
0
0
0
0
-19999
-19999
0
0
0
0
0
0
0
0
0
0
0
0
250
2
2
2
99999
99999
2
5
5
19
5
19
5
5
19
5
19
19
0
0
0
0
0
0
0
0
0
0
4
0
0
5
0
3
0
0
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
SEE MODULE 3 FOR DESCRIPTIONS OF PARAMETERS
DISPLAY/QUICK PRO MENU LOCKS
See User Input 1 above
0 = Lock, 1=Read, 2=Enter
0 = Lock, 1=Read, 2=Enter
0 = Lock, 1=Read, 2=Enter
*Value shown here for reference
*Value shown here for reference
0 = Lock, 1=Read, 2=Enter
SEE MODULE 4 FOR DESCRIPTIONS OF PARAMETERS
0=Loc, 1=Red, 2=Disp _, 3=Disp A, 4= Disp B, 5=Disp C
0=Loc, 1=Red, 2=Disp _, 3=Disp A, 4= Disp B, 5=Disp C
See User F1 Key Description
0=Loc, 1=Red, 2=Disp _, 3=Disp A, 4= Disp B, 5=Disp C
See User F1 Key Description
0=Loc, 1=Red, 2=Disp _, 3=Disp A, 4= Disp B, 5=Disp C
0=Loc, 1=Red, 2=Disp _, 3=Disp A, 4= Disp B, 5=Disp C
See User F1 Key Description
See User F1 Key Description
1=0.1 Second
Filter Band
ADC Conversion Rate (samples/sec)
Registers 40113-40168, 40213-40268 not shown but
follow ordering as shown for Input 1, Display 1
0=Loc, 1=Red, 2=Disp _, 3=Disp A, 4= Disp B, 5=Disp C
1
For Input Registers, replace the 4xxxx with a 3xxxx in the above register address. The 3xxxx are a mirror of the 4xxxx Holding Registers.
2
An attempt to exceed a limit will set the register to its high or low limit value.
23 = r-1
15 = r-HL
7 = A-HLd
30 = Print
22 = LISt
14 = r-Lo
6 = d-HLd
29 = r-ALL
21 = d-LEV
13 = r-HI
5 = b-drL
28 = r-234
20 = dSP-_
12 = E-tot
4 = A-drL
27 = r-34
19 = dSP-C
11 = rtot2
3 = b-rEL
26 = r-4
18 = dSP-b
10 = rtot1
2 = A-rEL
25 = r-3
17 = dSP-A
9 = bAt
1 = PLOC
24 = r-2
16 = dISP
8 = SYNC
0= NO
19 = Print
14 = r-3
9 = r-HL
4 = b-drL
18 = r-ALL
13 = r-2
8 = r-Lo
3 = A-drL
17 = r-234
12 = r-1
7= r-HI
2 = b-rEL
16 = r-34
11 = LISt
6 = rtot
1 = A-rEL
15 = r-4
10 = d-LEV
5 = bAt
0 = NO
0=Volt, 1=Current, 2=Volt Square Root Extraction,
3= Current Square Root Extraction