beautypg.com

Troubleshooting, Inp 1 2 key, Pts style 0.010 – NOSHOK 2100 Series Field Upgradeable Dual Input Process Indicator User Manual

Page 32: Band 1.0, Filtr 0.001, Round 0.000, Decpt 19.8 volt, Rate range

background image

32

TROUBLESHOOTING

CHECK: Active (lock-out) user input
ENTER: Security code requested

PRESS: Reset KEY (If cannot clear contact factory.)

ERROR CODE (Err xxx or EE xxx)

CHECK: Corresponding plug-in card installation

MODULES or PARAMETERS NOT ACCESSIBLE

INCREASE: Module 1 filtering, rounding, input range
CHECK: Wiring is per EMC installation guidelines

JITTERY DISPLAY

CHECK: Module 1 programming, Input Range Jumper position, input connections, input signal level

“ULUL” in DISPLAY (SIGNAL LOW)

CHECK: Module 1 programming, Input Range Jumper position, input connections, input signal level

“OLOL” in DISPLAY (SIGNAL HIGH)

CHECK: Module 1 programming, Input Jumper position, input connections, input signal level,

Module 4 Display Offset is zero, press DSP for Input Display

PERFORM: Module 9 Calibration (If the above does not correct the problem.)

INCORRECT INPUT DISPLAY VALUE

CHECK: Module 3 programming

DISPLAY LOCKED-OUT

PROGRAM LOCKED-OUT

CHECK: Power level, power connections, Module 3 programming

NO DISPLAY

REMEDIES

PROBLEM

1-INP

Signal

Input Parameters

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

INPUT VALUE 3

INPUT VALUE 5

INPUT VALUE 4

INPUT VALUE 6

DISPLAY VALUE 3

DISPLAY VALUE 5

DISPLAY VALUE 4

DISPLAY VALUE 6

INP 3

INP 5

INP 4

INP 6

dSP 3

dSP 5

dSP 4

dSP 6

10.000

DISPLAY VALUE 2

dSP 2

10.000

INPUT VALUE 2

INP 2

0.000

DISPLAY VALUE 1

dSP 1

0.000

INPUT VALUE 1

INP 1

2

KEy

SCALING POINTS

SCALING STYLE

PtS

StyLE

0.010

FILTER ENABLE BAND

bANd

1.0

FILTER SETTING

FILtr

0.001

DISPLAY ROUNDING
INCREMENT

round

0.000

DISPLAY RESOLUTION

dECPt

19.8

VoLt

UPDATE RANGE

INPUT RANGE

rAtE

rANGE

INPUT B

USER SETTING

INPUT A

USER SETTING

FACTORY

SETTING

PARAMETER

DISPLAY

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

0.000

INPUT VALUE 7

DISPLAY VALUE 12

INPUT VALUE 9

DISPLAY VALUE 14

INPUT VALUE 8

DISPLAY VALUE 13

DISPLAY VALUE 11

INPUT VALUE 10

DISPLAY VALUE 15

DISPLAY VALUE 7

INPUT VALUE 13

INPUT VALUE 11

DISPLAY VALUE 9

DISPLAY VALUE 16

INPUT VALUE 15

DISPLAY VALUE 8

INPUT VALUE 14

INPUT VALUE 12

DISPLAY VALUE 10

INPUT VALUE 16

INP 7

dSP 12

INP 9

dSP 14

INP 8

dSP 13

dSP 11

INP 10

dSP 15

dSP 7

INP 13

INP 11

dSP 9

dSP 16

INP 15

dSP 8

INP 14

INP 12

dSP 10

INP 16

INPUT A

USER SETTING

FACTORY

SETTING

PARAMETER

DISPLAY

INPUT B