beautypg.com

KROHNE CORIMASS E Series EN User Manual

Page 19

background image

19

4.2

4.1

4

6

5

R

ext

Pulse Output

Common

Screened Cable

OV

88888888

+

_

COUNTER

C

ext

(10 - 100nF if required)

V

ext (Max. 24 V DC)

R

ext >

V

ext

0.15

Fig. 23:

Connection with external voltage source

4.2

4.1

4

6

5

R

ext

(> 800 ohm)

Pulse Output

Common

Screened Cable

OV

88888888

+

_

COUNTER

C

ext

(10 - 100nF if required)

Fig. 24:

Connection using converter internal voltage source

Additional input/output options

No.

Option 4
(2 current,
pulse and
input)

Option 5
(3 current
and
pulse)

Option 6
(3 current
and
input)

Option 7
(3 current
and
alarm

Option B

*

(Current
and
RS485)

Option C

**

(1 Current,
1 Dual
phase pulse
output and
input)

5

Common
(-)

Common
(-)

Common
(-)

Common
(-)

Common
(-)

Common
(-)

6

Current
output (+)

Current
output 1 (+)

Current
output 1 (+)

Current
output 1 (+)

Current
output 1 (+)

Current
output 1 (+)

4

Current
output 2 (+)

Current
output 2 (+)

Current
output 2 (+)

Current
output 2 (+)

TX/RX

Control
Input

4.1

Control
Input

Current
output 3
(+)

Current
output 3
(+)

Current
output 3
(+)

TX/RX

Pulse
Output A

4.2

Pulse
Output

Pulse
output

Control
Input

Alarm
output
(passive)

+5V

Pulse
Output B

*

Refer to separate RS 485 manual

**

Refer to separate manual for this output option.

This manual is related to the following products: