KROHNE BATCHCONTROL 5014 C User Manual
Page 38

Installation and operating instructions
38 BATCHCONTROL
Object
No
Index
Value (def
ault)
D
esc
ri
pti
on
D
imensi
on
For
mat
min
max
access
Desc
ripto
r
transfe
r
Desc
ript
ion
1 = counter 
operates 
Bit
1:
Counter
reset
0
=
no
function
1 = reset the 
counter 
3091H 05H
0
Controlling batching 
process 
without byte 0
3 w - d
Bit 0: 1 = Start filling through bus, 
only at batching process = CAN 
Bus (0 = without function) 
Bit 1: 1 = Stop filling through bus, 
independent from other inputs (0 = 
without function) 
3091H 06H
0
Learning function
-
byte
0
3
r/w
-
d
Self learning function
Bit
1-0:
Activation
of
function
0
=
function
off
1
=
not
allowed
2 = function on, 
no other action 
3 = function on 
and the next 
filling starts the 
self learning cycle
3091H 07H
0
Function select for ‘switch 
off calculation’ 
-
byte
0
1
r/w
-
d
Programm select for switch off 
calculation 
0 = switch off point depends from 
the last 1 to 5 tail volumes 
1 = switch off point depends from 
the actual flow and the last 1 to 5 
tail volumes 
3091H 08H
0
Function data 1
-
byte
0
5
r/w
-
d
First data for the function ‘switch off 
calculation’ 
Fct = 0: number of tail volumes for 
switch off calculation (1 to 5) 
Fct = 1: number of tail volumes for 
switch off calculation (1 to 5) 
3091H 09H
0
Function data 2
-
byte
0
255
r/w
-
d
Second data for the function ‘switch 
off calculation’ 
(for future use) 
3091H 0AH 0,001
Volume flow value for 
switch off 
l/s float
0
15,1
r/w
- d
If the volume flow is lower then this 
value, the filling will stop after 
number of measurements 
3091H 0BH
10
Number of measurements
byte
1
100
r/w
-
d
Parameter for the function 3091.10
3091H 0CH
0 Definition
for
shut-down
without
byte
0
63
r/w
-
d
Bit 0: 1 = output 1 switch off if 
3091_05 Bit 1 = 1 , 0 = no 
influencing of the output 
Bit 1: 1 = output 2 switch off if 
3091_05 Bit 1 = 1, 0 = no 
influencing of the output 
Bit 2: 1 = output 3 switch off if 
3091_05 Bit 1 = 1 , 0 = no 
influencing of the output 
Bit 3: 1 = output 4 switch off if 
3091_05 Bit 1 = 1, 0 = no 
influencing of the output 
Bit 4: 1 = output 5 switch off if 
3091_05 Bit 1 = 1, 0 = no 
influencing of the output 
Bit 5: 1 = output 6 switch off if 
3091_05 Bit 1 = 1, 0 = no 
influencing of the output 
3091H 0DH
100 Fixed tail volume 1
ml
byte
0
255
r/w
-
d
this tail volume is used for the next 
filling (if the bit 4 is set in RPDO1) 
and after power on 
3091H 0EH
100 Fixed tail volume 2
ml
byte
0
255
r/w
-
d
this tail volume is used for the next 
filling (if the bit 5 is set in RPDO1) 
3091H 0FH 10
Percentage of target 
volume 
% byte
0 50
r/w
- d
this tail volume is used for the next 
filling (if the bit 6 is set in RPDO1) 
3092H Status values and PDO definition
3092H 00H
2
Number of entries
without
byte
-
-
r
-
d
3092H 01H
0
Actual status of batching without
byte
0 5 r
91H
-
Bit
0-3:
actual
status
of
batching
0
=
stop
