KROHNE BATCHCONTROL 5014 C User Manual
Page 37
Installation and operating instructions
BATCHCONTROL
Object
No
Index
Value (def
ault)
D
esc
ri
pti
on
D
imensi
on
For
mat
min
max
access
Desc
ripto
r
transfe
r
Desc
ript
ion
1000 = switch off
by analogue
voltage
1001 = switch off
by batch program
1010 = switch off
by error detected
1011 = switch off
by customer
program
30y4H 06H
0,001
s
Off value
l or s or l/s
or V or °C
float
0s
0l
0l/s
0V
-20°C
100s
100l
15l/s
11V
120°C
r/w - d
According to selected function: off
time or volume or volume flow or
temperature or voltage
30y4H
07H
0
Input channel for off signal without byte 0 21 r/w - d
Bit 0-3: input channel for output off
function
0000
=
function
1
0001
=
function
2
0010
=
function
3
0011
=
function
4
0100
=
function
5
0101
=
function
6
Bit
4:
Calculation
function
0 = input >
parameter
1 = input <
parameter
30y4H
08H
0
Status of output
without
byte
0
7
r/w
y4H
-
Bit 0: actual status of output
0
=
output
is
off
1
=
output
is
on
Bit
2-1:
error
status
of
output
00
=
no
error
01 = short circuit
(only detected if
output is on)
10 = interruption
(only detected if
output is on)
11 = chip
temperature to
high
30y4H 09H
4
Sending function for Index
08H
without byte 0
4 r/w - d
Bit 3-0: Sending function change of
status
Bit
1-0:
Priority
00
=
PDO
0
01
=
PDO
1
10
=
PDO
2
11
=
PDO
3
Bit
2:
activation
of
function
1 = no message
output
0 = activation of
message output
309xH Batching
3091H Filling parameter
3091H 00H
15
Number of entries
without
byte
-
-
r
-
d
3091H 01H 0,5 Target
volume l
float
0,0001
200
r/w
-
d
Automatic output controls on this
parameter
3091H 02H
0,02 Forward run time
s
float
0.01
10
r/w
-
d
Time after starting, before opening
of valve
3091H 03H 0,5 Time
out
s
float 0.01
10
r/w
-
d
Time after filling, before a new run
instruction is accepted
3091H 04H
1 Counter
control
without
byte
0
3
w
-
d
Counter control (only active on
manual control output))
Bit
0:
Start/Stop
Counter
0
=
stop
counter