KROHNE BATCHCONTROL 5014 C User Manual
Page 32

Installation and operating instructions
32 BATCHCONTROL
Object
No
Index
Value (def
ault)
D
esc
ri
pti
on
D
imensi
on
For
mat
min
max
access
Desc
ripto
r
transfe
r
Desc
ript
ion
volume is to high, 0 = no
influencing of the output
Bit 1: 1 = output 2 switch off if
volume is to high, 0 = no
influencing of the output
Bit 2: 1 = output 3 switch off if
volume is to high, 0 = no
influencing of the output
Bit 3: 1 = output 4 switch off if
volume is to high, 0 = no
influencing of the output
Bit 4: 1 = output 5 switch off if
volume is to high, 0 = no
influencing of the output
Bit 5: 1 = output 6 switch off if
volume is to high, 0 = no
influencing of the output
3003H 07H
- Actual
status
without byte 0
1 r 05H -
Bit 0: 1 = Limit value exceeded, 0 =
okay
3003H 08H
4
Sending function for Index
07H
without byte 0
4 r/w - d
Bit
1-0:
Priority
00
=
PDO
0
01
=
PDO
1
10
=
PDO
2
11
=
PDO
3
Bit
2:
activation
of
function
1 = no message
output
0 = activation of
message output
301xH Electronic temperature sensor
3011H Sensor parameter
3011H
00H
2
Number
of
entries
without
byte - - r - -
3011H 01H
1.0
Factor for scaling without
float
0,001
1000,
0
r/w - d
3011H 02H
0.0
Offset for scaling
°C float
-100,0
100,0
r/w
- d
3012H Measurement values and PDO definition
3012H
00H
3
Number
of
entries
without
byte - - r - -
3012H 01H 0,0 Measuring
value
°C
float
-10 +100 r 11H - actual
measured
temperature
3012H 02H
4
Sending function for index
01H
without byte 0
4 r/w - d
Sending function of temperature
output (repeat time depends on
index 3)
Bit
1-0:
Priority
00
=
PDO
0
01
=
PDO
1
10
=
PDO
2
11
=
PDO
3
Bit
2:
activation
of
function
1 = no message
output
0 = activation of
message output
3012H 03H
250 Repeat time
ms
word
50
5000
r/w
-
d
Repeat time for the value
3013H Alarm values and PDO definition
3013H
00H
4
Number
of
entries
without
byte - - r - -
3013H 01H
20
Lower limit value
°C
float
-10
+80
r/w
-
d
Warning message when value
remains below limit
3013H 02H
70
Upper limit value °C
float
0
+100
r/w
-
d
Warning message when value
exceeds limit
3013H 03H
0
Status of measuring input without
byte 0 15 r 12H -
Bit 0: 1 = lower limit value is
exceeded
Bit 1: 1 = upper limit value is
exceeded
Bit
2:
1
=
sensor
cable
break
Bit
3:
1
=
sensor
short
circuit
3013H 04H
4
Sending function for index
03H
without byte 0
4 r/w - d
Sending function change of status