KROHNE BATCHCONTROL 5014 C User Manual
Page 18
Installation and operating instructions
18 BATCHCONTROL
volume.
Output ‘3’ is used for the carbonizing of the bottle. This valve ist used at the beginning of
the filling process. It opens for 0,6 second.
Output ‘4’ is used for unpreasurizing the bottle at the end of the filling process. It opens for
1 second.
Output ‘5’ an ‘6’ are not used.
CAN PARAMETER
Letter Object
No.
Description
output 1
3031.01
Function of the block
3034.01
Output hardware function
output 2
3041.01
Function of the block
3044.01
Output hardware function
output 3
3051.01
Function of the block
3054.01
Output hardware function
output 4
3061.01
Function of the block
3064.01
Output hardware function
output 5
3071.01
Function of the block
output 6
3081.01
Function of the block
The following graphic shows the timing diagram of the filling process.
time parameter
-0,02
0,00
0,02
0,04
0,06
0,08
0,10
0,12
0,14
0,16
0,00
2,00
4,00
6,00
8,00
10,00
12,00
14,00
16,00
18,00
t[s]
Q[l/s]
A B
C D
E F G H I
J
output 1
output 2
output 3
output 4
At the time of ‘A’ the filling starts. The bottle gets pressurized with CO2 (‘B’ – ‘C’). After this both
product valves opens at the time of 'D'. The high speed valve is closed after 950ml (‘E’) is filled.
The low speed valve is closed at the time of 'F' and the filling is completed to 'G'. The last step is to
depressurize the bottle ('H' – ‘I’). The next filling starts after 'J'.
CAN PARAMETER
Letter Object
No.
Description
A
3091.05
Controlling batching process
B
3054.02
Output 3 on function definition
3054.03
On value (output 3)
C
3054.05
Output 3 off function definition
3054.06
Off value (output 3)
D
3091.02
Forward run time
3034.02
Output 1 on function definition
3044.02
Output 2 on function definition
E
3044.05
Output 2 off function definition
3044.06
Off value (output 2)
F
3034.05
Output 1 off function definition
G
3091.07
Function select ‘switch off calculation’
3091.08
Function
data
1
3091.0A
Volume flow value for switch off
3091.0B
Number of measurements
3091.0C
Definition for shut-down
4