beautypg.com

Can parameter – KROHNE BATCHCONTROL 5014 C User Manual

Page 19

background image

Installation and operating instructions

19

BATCHCONTROL

H

3064.02

Output 4 on function definition

3064.03

On value (output 4)

I

3064.05

Output 4 off function definition

3064.06

Off value (output 4)

G – J

3091.03

Time out


There are parameters similar as in the case of the time representation, for the supervision of the
volume flow.

volume flow parameter

-0,02

-0,01

0,00

0,01

0,02

0,03

0,04

0,05

0,06

0,07

0,08

0,09

0,10

0,11

0,12

0,13

0,14

0,15

0,16

0,00

2,00

4,00

6,00

8,00

10,00

12,00

14,00

16,00

18,00

t[s]

Q[l

/s

]

flow

max. limit flow

max. flow

Q100%

A

B

C


‘A’ is the full scale range of the flow meter. An overload of +50% is permitted. If the flow should get
even bigger, then the value is limited to150%. The value 'B' is an emergency switch off value for
the valve. The value 'C' corresponds to the maximum volume flow during the filling process.

CAN PARAMETER

Letter Object

No.

Description

A

3001.01

Full scale range

B

3003.01

Maximum volume flow

C 3094.06

Maximum

flow

velocity


The internal volume counter adds up the measurement values. As in the case of the two previous
representations the counter has own parameters.

volume parameter

(internal counter)

0,00

0,20

0,40

0,60

0,80

1,00

1,20

0,00

2,00

4,00

6,00

8,00

10,00

12,00

14,00

16,00

18,00

t[s]

v

o

lume

[

m

l]

A

F

G

H

I

B

C D

E


At the time of ‘A’ the filling starts. The bottle gets pressurized with CO2. After this both valves open
for the product at the time of 'B'. The valve reduces the flow speed at the position of 'C' and the

4