Installation and operating instructions
19
BATCHCONTROL
H
3064.02
Output 4 on function definition
3064.03
On value (output 4)
I
3064.05
Output 4 off function definition
3064.06
Off value (output 4)
G – J
3091.03
Time out
There are parameters similar as in the case of the time representation, for the supervision of the
volume flow.
volume flow parameter
-0,02
-0,01
0,00
0,01
0,02
0,03
0,04
0,05
0,06
0,07
0,08
0,09
0,10
0,11
0,12
0,13
0,14
0,15
0,16
0,00
2,00
4,00
6,00
8,00
10,00
12,00
14,00
16,00
18,00
t[s]
Q[l
/s
]
flow
max. limit flow
max. flow
Q100%
A
B
C
‘A’ is the full scale range of the flow meter. An overload of +50% is permitted. If the flow should get
even bigger, then the value is limited to150%. The value 'B' is an emergency switch off value for
the valve. The value 'C' corresponds to the maximum volume flow during the filling process.
CAN PARAMETER
Letter Object
No.
Description
A
3001.01
Full scale range
B
3003.01
Maximum volume flow
C 3094.06
Maximum
flow
velocity
The internal volume counter adds up the measurement values. As in the case of the two previous
representations the counter has own parameters.
volume parameter
(internal counter)
0,00
0,20
0,40
0,60
0,80
1,00
1,20
0,00
2,00
4,00
6,00
8,00
10,00
12,00
14,00
16,00
18,00
t[s]
v
o
lume
[
m
l]
A
F
G
H
I
B
C D
E
At the time of ‘A’ the filling starts. The bottle gets pressurized with CO2. After this both valves open
for the product at the time of 'B'. The valve reduces the flow speed at the position of 'C' and the